Finder Contactor - 25A 2NO 24V AC/DC - 22 Series




Best current price£24.20from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Finder Modular Contactor 25A 24V Dc/Ac 2Nc With Led Indicator - 22.32.0.024.4420
Visit shop



Best current price£24.20from Tameson UK
Shopping.co.uk recommended and popular offers
Finder Modular Contactor 25A 24V Dc/Ac 2Nc With Led Indicator - 22.32.0.024.4420
Visit shop33 offers from £24.20 - £93.55
View price history by clicking the chart icon.
The Finder 22 Series Contactor (Model 22.32.0.024.4320) is designed for electricians and automation professionals needing a compact, reliable solution for controlling lighting and general electrical loads. Its primary benefit is its space-saving 17.5mm modular design and noiseless operation. A key consideration is its specific contact rating and voltage requirements, making it ideal for applications within its specified limits.
| Series | 22 Series |
|---|---|
| Model Part Number | 22.32.0.024.4320 |
| Brand | Finder |
The contactor has a maximum switching power of 6.25 kVA (AC) and can handle a maximum switching voltage of 440V AC with a current capacity of 25A.
No, this specific model (22.32.0.024.4320) features two normally open (NO) contacts and does not have any normally closed (NC) contacts.
This contactor is designed to be mounted on a standard 35mm DIN rail.
The coil resistance is approximately 41 Ω for AC operation and 460 Ω for DC operation. This difference affects the power consumption calculation for each type of supply.
No, the contactor has a degree of protection of IP20, meaning it is protected against solid objects larger than 12.5mm but offers no protection against water. It should be installed in a suitable enclosure to protect it from environmental factors.
Warranty information is typically provided by the retailer or distributor. Please refer to your purchase documentation for specific warranty details.
Yes, the 22 Series contactors are designed to allow for additional equipment, which can include auxiliary contact blocks. Ensure compatibility before purchasing and installing accessories.
Verify the coil voltage is exactly 24V AC or 24V DC and is correctly connected to A1/A2 terminals. Check for loose connections or a broken wire in the control circuit. Ensure the coil is not faulty.
Disconnect power immediately. This may indicate a short circuit in the load or a failure within the contactor. Inspect the load circuit for faults. The contactor may need replacement if the internal contacts are damaged.
Ensure the load current does not exceed the 25A rating. Check for adequate ventilation around the contactor, especially in enclosed spaces. If the coil is continuously energized, verify the coil power consumption is within specifications (2.2W).
Confirm the coil is energized with the correct voltage. The LED may be faulty, or the contactor might be functioning but the indicator is not showing it. Check the connection to the LED if accessible, otherwise, the unit may require replacement.
Setup:
Compatibility:
Care: