Professional brass cable gland designed for cable diameters up to 98mm, specifically engineered fo...Professional brass cable gland designed for cable diameters up to 98mm, specifically engineered for environments requiring high mechanical and chemical stability. Ideal for chemical industry, control systems, machinery manufacturing, and installation applications where reliable cable management is crucial. Locknuts are not included and must be ordered separately. EAN: 4044774405056 - manufacturer-number: MS-M75x1,5 - Cable gland / core connector M75 Thread type Metric, Nominal thread size metric/PG 75, Suitable for cable diameter 58 ... 68mm, Material Metal, Material quality Brass, Surface treatment Nickel-plated, Degree of protection (IP) IP68, Colour Natural colour, Model Straight, Type of sealing Sealing ring, Operating temperature -30 ... 100°C, For Ex-zone gas None, For Ex-Zone dust None - MS-M 75x1,5
Best current price£3.37from Rapid Online - Rapid Electronics Ltd.
The LAPP SKINTOP MS-M 75x1.5 cable gland is designed for professionals in demanding industrial environments. It offers superior mechanical strength and chemical resistance, ensuring reliable cable entry and protection, especially in chemical plants, control systems, and machinery manufacturing. A key consideration is that locknuts are sold separately and must be acquired prior to installation.
All features
Model Part Number
53112510
Brand
Lapp
Extended Product Information
FAQs
What is the primary benefit of using this cable gland?
Its primary benefit is providing robust, sealed cable entry in environments that demand high mechanical strength and resistance to chemicals and harsh conditions, with an IP68/IP69 rating for superior protection.
Are locknuts included with the cable gland?
No, locknuts are not included and must be ordered separately.
What is the maximum cable diameter this gland can accommodate?
This gland is designed for cable diameters ranging from 58mm up to 68mm.
Can this gland be used in explosive atmospheres (Ex-zones)?
This specific model is not rated for Ex-zones (gas or dust).
What is the operating temperature range for this cable gland?
The operating temperature range is from -30°C to 100°C.
What material is the cable gland made from?
The primary material is brass, with a nickel-plated surface treatment. Some internal components may include polyamide.
How do I ensure a proper seal?
Ensure the cable diameter is within the specified range, the sealing ring is correctly positioned, and the gland is securely tightened into the enclosure using the appropriate locknut.
Troubleshooting
Difficulty tightening the gland into the M75 opening.
Ensure the M75 threaded opening is clean and free from debris. Verify that the thread type on the gland matches the opening precisely.
Cable is loose within the gland.
Check if the cable diameter is within the specified range (58-68mm). Ensure the sealing ring is correctly seated and try tightening the gland further to compress the seal around the cable.
Water or dust ingress detected despite installation.
Verify that a locknut (sold separately) was used and tightened correctly. Ensure the sealing insert is fully engaged with the cable and the gland itself is properly sealed to the enclosure.
Corrosion observed on the gland surface.
While designed for chemical resistance, prolonged exposure to extremely aggressive substances or damage to the nickel plating may cause superficial corrosion. Clean gently and monitor for further degradation. Consider alternative materials if the environment is exceptionally harsh.
Pros and Cons
Pros
Exceptional durability and resistance to mechanical stress.
Excellent protection against dust and water (IP68/IP69).
Suitable for a wide range of industrial and chemical environments.
High-quality brass construction ensures a long service life.
Standardized metric thread for easy integration.
Cons
Locknuts are not included and must be purchased separately.
Limited flexibility for very small or extremely large cable diameters beyond the specified range.
Can be heavier than plastic alternatives.
Setup, Compatibility & Care
Setup:
Ensure the mounting surface has a clean M75x1.5 threaded opening.
If not already attached to the gland, install a compatible locknut (sold separately) onto the threaded portion of the gland.
Insert the cable through the sealing insert, ensuring the cable diameter is within the 58mm to 68mm range.
Thread the cable gland into the M75x1.5 opening, tightening securely to achieve a proper seal.
Tighten the locknut from the inside of the enclosure to secure the gland in place.
Compatibility:
Thread Size: Compatible with M75x1.5 metric threads.
Cable Diameter: Suitable for cables with diameters ranging from 58mm to 68mm.
Environment: Ideal for applications requiring high mechanical and chemical stability, including industrial, chemical, and machinery environments.
Locknuts: Requires a separate M75 locknut for secure installation.
Care:
Periodically inspect the cable gland for any signs of damage or wear.
Clean the exterior with a damp cloth. Avoid abrasive cleaners that could damage the nickel plating.
Ensure the seal remains intact and properly seated around the cable.