Omron MY4 14-Pin Plug-in Relay - 4PDT 6A 24VAC

Best current price£10.03from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Omron My4 14-Pin Plug-In Relay 4Pdt 6A 24Vac - My4 5700A
Visit shop
Best current price£10.03from Tameson UK
Shopping.co.uk recommended and popular offers
Omron My4 14-Pin Plug-In Relay 4Pdt 6A 24Vac - My4 5700A
Visit shop1 offer from £10.03
View price history by clicking the chart icon.
This professional-grade Omron MY4 relay is designed for industrial automation and control systems requiring reliable switching of multiple circuits. It offers a 4PDT (four-pole double-throw) configuration with a 24 VAC coil and 6A current capacity, allowing for complex control logic and power distribution. A key benefit is its visual mechanical indicator for easy status monitoring. One caveat is its specific 14-pin base, requiring a compatible socket.
| Brand | Omron |
|---|
4PDT stands for Four-Pole Double-Throw. It means the relay has four independent sets of contacts, and each set can connect to either of two terminals (Normally Open or Normally Closed).
No, the Omron MY4 relay is sold separately from its required 14-pin socket. You will need to purchase a compatible 14-pin socket.
The nominal current capacity is 6A. The maximum switching voltage is 250 VAC or 220 VDC.
This model features a mechanical indicator, often called a flag, that visually shows whether the relay coil is energized and the contacts have switched.
Yes, it can switch DC loads up to 220V and a corresponding current rating suitable for DC at that voltage, however, the primary rating specified is 6A nominal.
Monostable means the relay returns to its default de-energized state when the coil voltage is removed. It requires continuous power to the coil to maintain its energized state.
The coil resistance for this 24 VAC version is approximately 180 Ohms.
Verify the 24 VAC control voltage is present at the coil terminals (A1/A2) of the socket. Check wiring connections to the socket and ensure the relay is fully seated. Confirm the coil resistance is within specification if possible.
Ensure the relay is correctly seated in the socket. Check that the control voltage is sufficient to energize the coil. If the relay has been in service for a long time, the contacts may be worn or damaged.
This typically indicates the relay coil is not being energized or the internal mechanism is faulty. Follow steps for 'Relay does not energize'.
Check for loose wiring connections which can cause high resistance. Ensure the load current does not exceed the 6A rating. Verify the correct relay type is used for the application.
Setup:
Compatibility:
Care: