LavaTap Air Admittance Valve - 32/40/50mm - Push Fit and Solvent Weld

The LavaTap air admittance valve is a high-performance internal waste vent designed to regulate pr...

Best current price£15.99from eBay

All Offers

4 offers from £15.99 - £17.99

View price history by clicking the chart icon.

eBayLavaTap Air Admittance Valve 32mm 40mm 50mm Solvent Weld Waste Pipe Vent Black
Free delivery in 1–3 days
£15.99
Visit shop
B&QB&Q - Air Admittance Valve 32/40/50mm Internal Vent Push Fit And Solvent Weld Systems
Free delivery in 1–3 days
£17.99
Visit shop

Product Information

Full details

The LavaTap Air Admittance Valve (AAV) is designed for homeowners and plumbers seeking an efficient internal waste vent solution. Its primary benefit is preventing trap siphoning and foul odors by regulating air pressure in drainage systems. A key consideration is that it is designed for internal use only and must be installed above the highest water outlet. This versatile valve acts as a 3-in-1 solution, accommodating 32mm, 40mm, and 50mm waste pipes with an included adaptor, supporting both push-fit and solvent weld installations for seamless integration into various plumbing setups.

All features

Model Part NumberLAVA0050
BrandLavaTap

Extended Product Information

FAQs

Can this valve be used for external venting?

No, the LavaTap Air Admittance Valve is designed and approved for internal use only. It must be installed within the building's heated envelope and above the flood level of connected fixtures.

What size waste pipes does it fit?

The valve is a universal fit for 32mm, 40mm, and 50mm waste pipes, utilizing an included stepped adaptor for versatile compatibility.

How do I clean the LavaTap AAV?

Simply unscrew the top cap counter-clockwise to access the internal mechanism. Remove any debris and wipe clean with a damp cloth. Re-secure the cap firmly afterward.

What is the main function of an Air Admittance Valve?

An AAV automatically admits air into the drainage system when negative pressure occurs, preventing trap siphoning and the release of foul odors into the living space.

Can I use solvent weld and push-fit connections on the same valve?

The valve itself is designed to accommodate both push-fit and solvent weld methods. However, the connection *to* the pipework must be consistent (e.g., use push-fit fittings for push-fit pipe, and solvent weld for solvent weld pipe) unless specific transition fittings are used.

Where exactly should I install it?

Install the valve vertically on a waste pipe, ensuring it is positioned higher than the water level in the trap of the highest fixture connected to that waste pipe.

Does it require electricity or power?

No, the LavaTap AAV operates passively using the natural pressure changes within the drainage system. It does not require any external power source.

Troubleshooting

Persistent foul odors

Verify the AAV is installed vertically and above the highest fixture's flood level. Check that the cap is securely fitted and clean any debris from the valve mechanism. Ensure no other venting issues exist in the system.

Slow draining or gurgling sounds

Confirm the valve is functioning by checking for proper air admittance. Ensure the valve is not blocked internally and that the pipework is not obstructed. The valve might be undersized for extremely high flow rates or incorrectly positioned.

Valve does not appear to be sealing properly

Ensure the valve is installed in the correct orientation (vertical) and that the cap is fully secured. Debris or damage to the sealing mechanism could be the cause; clean or replace if necessary.

Pros and Cons

Pros

  • Highly versatile with 3-in-1 pipe size compatibility.
  • Supports both push-fit and solvent weld for broad application.
  • Effectively prevents foul odors and protects trap seals.
  • Compact design is suitable for tight installation spaces.
  • Easy to install and maintain with a removable cap.

Cons

  • Strictly for internal use; cannot be installed externally.
  • Requires installation above the highest water outlet for proper function.
  • May require specific knowledge of plumbing for optimal solvent weld installation.
  • ABS material, while durable, might be perceived as less premium than metal alternatives.

Setup, Compatibility & Care

Setup:

  1. Ensure the valve is installed vertically on a waste pipe section.
  2. Position the valve *above* the flood level rim of the highest connected fixture (e.g., sink, toilet, shower).
  3. For 32mm, 40mm, or 50mm pipework, attach the included adaptor as needed.
  4. Integrate the valve into the waste pipe system using either push-fit connections or solvent weld methods, following standard plumbing practices for each.

Compatibility:

  • Compatible with standard 32mm, 40mm, and 50mm PVC or ABS waste pipes.
  • Supports both push-fit (compression) and solvent weld jointing techniques.
  • Designed for internal plumbing systems only.

Care:

  • Periodically, remove the top cap (unscrew counter-clockwise) to inspect and clean any debris from the valve mechanism.
  • Use a damp cloth to clean the exterior. Avoid abrasive cleaners.
  • Ensure the removable cap is securely re-fastened after maintenance.

Price History

DatePrice
Visit shop