Finder 4C Interface Relay - 24VDC 8A Dual CO LED

Interface relay module featuring dual changeover contacts rated at 8A/250VAC, operating on 24V DC ...

Best current price£13.78from eBay

All Offers

20 offers from £13.78 - £23.74

View price history by clicking the chart icon.

eBayFinder Relay 2CO 12VDC
£3.50 delivery
£13.78
Visit shop
Tameson UKFinder 16A Interface Relay Module 12V Dc With Led - 4C.01.9.012.0050
Free delivery in 1–3 days
£14.40
Visit shop
Rapid Online - Rapid Electronics Ltd.Finder 4C.02.9.012.0050 Relay 2CO 12VDC
Free delivery in 1–3 days
£14.72
Visit shop

Product Information

Full details

This guide is for engineers, technicians, and automation specialists who need reliable signal switching in industrial control systems. The Finder 4C Interface Relay provides dependable dual changeover functionality with a 24V DC coil, offering a robust solution for circuit control and isolation. A key consideration is its specific 24V DC coil requirement, meaning it is not interchangeable with AC powered relays without an appropriate power supply modification.

All features

Series4C
Model Part Number4C.02.9.024.0050
BrandFinder

Extended Product Information

FAQs

What is the purpose of the integrated flyback diode?

The flyback diode, also known as a suppression diode, is connected in reverse bias across the relay coil. When the coil is de-energized, it prevents the collapse of the magnetic field from generating a high-voltage spike that could damage sensitive control electronics.

Can this relay switch AC loads?

Yes, the contacts are rated for 250VAC, making them suitable for switching AC loads within the 8A limit.

What is the difference between a DPDT and SPDT relay?

DPDT stands for Double Pole Double Throw, meaning it has two independent sets of contacts (double pole), each with a common terminal, a normally open terminal, and a normally closed terminal (double throw). SPDT (Single Pole Double Throw) has only one set of such contacts.

How do I identify the coil terminals?

The coil terminals are typically marked with 'A1' and 'A2'. Refer to the wiring diagram on the relay or its datasheet for precise identification. For this 24V DC model, ensure correct polarity is applied.

What is the contact material, and why is it important?

The contact material is AgNi (Silver Nickel). This material offers a good balance of conductivity, resistance to arc erosion, and mechanical strength, making it suitable for general-purpose switching applications.

Can I manually override the relay?

This specific model (4C.02.9.024.0050) does not feature a manual override button. The relay is controlled solely by the application of voltage to its coil.

What mounting methods are supported?

This relay is designed for mounting on a standard 35 mm DIN rail according to the EN 60715 standard.

Troubleshooting

Relay does not energize when coil voltage is applied

Verify that the coil voltage is exactly 24V DC. Check wiring connections to A1 and A2 terminals for proper contact and polarity. Ensure the power supply is functioning correctly.

Contacts are stuck and do not switch

Ensure the coil voltage is correctly applied. Check if the load connected to the contacts exceeds the 8A rating. Inspect for physical damage or foreign objects obstructing contact movement. If issues persist, the relay may need replacement.

LED status indicator does not light up

Confirm that 24V DC is applied to the coil terminals with correct polarity. The LED is typically connected in parallel with the coil; if the coil is energized, the LED should illuminate. If not, the LED may be faulty or the coil voltage is insufficient.

Intermittent switching or poor contact

Check for loose wire connections on the screw terminals. Ensure the load current does not exceed the relay's capacity. Environmental factors like vibration or extreme temperatures can affect performance; ensure stable operating conditions.

Pros and Cons

Pros

  • Reliable switching with DPDT contacts
  • Clear visual status indication via LED
  • Integrated protection circuit (flyback diode)
  • Standard DIN rail mounting for easy integration
  • Durable AgNi contact material for longevity

Cons

  • Specific 24V DC coil voltage requirement
  • Contact rating may be insufficient for high-power loads
  • Requires a separate 24V DC power source
  • No manual override switch

Setup, Compatibility & Care

Setup

  1. Mounting: Secure the relay module onto a 35 mm DIN rail (EN 60715) by snapping it into place.
  2. Wiring: Connect the control voltage (24V DC) to the coil terminals (typically marked 'A1' and 'A2'). Ensure correct polarity.
  3. Contact Wiring: Wire your input signals and output loads to the appropriate changeover contacts (e.g., 1, 2, 3 for one set; 4, 5, 6 for the other).
  4. Power Up: Apply the 24V DC coil voltage to energize the relay.

Compatibility

  • Coil Voltage: Requires a stable 24V DC power source. Ensure your power supply meets this requirement.
  • Load Type: Suitable for switching resistive and moderate inductive loads within its 8A/250VAC rating. For heavy inductive loads, consider derating or using a higher-rated relay.
  • Environment: Operate within specified temperature and humidity ranges (refer to datasheet for specifics) to ensure optimal performance and longevity.

Care

  • Cleaning: Keep the relay and surrounding area clean and free from dust and debris. Use a dry cloth for cleaning. Avoid using solvents or liquids.
  • Inspection: Periodically inspect wiring connections for tightness and signs of corrosion or overheating.
  • Ventilation: Ensure adequate ventilation around the relay, especially if mounted in an enclosed panel, to prevent overheating.

Price History

DatePrice
Visit shop