APC Rack PDU 2G Metered by Outlet with Switching - Black

APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-cu...

Best current price£526.46from eBay

One Offer

1 offer from £526.46

View price history by clicking the chart icon.

eBayAPC AP8681 Power Distribution Unit PDU 24 AC outlets Rack Mountable 0U Black
Free delivery in 1–3 days
£526.46
Visit shop

Product Information

Full details

This APC Rack PDU 2G is designed for IT professionals in data centers and server rooms needing advanced power management and monitoring. It offers individual outlet control, real-time metering, and power sequencing to optimize uptime and prevent overloads. A key benefit is the granular control and visibility into power consumption per device. One potential consideration is its 400V nominal input voltage, requiring a compatible power infrastructure.

All features

ColourBlack
Model Part NumberAP8681
BrandA.P.C.

Extended Product Information

FAQs

What is the difference between Metered, Metered-by-Outlet, and Switched PDUs?

Metered PDUs provide an overall power reading for the unit. Metered-by-Outlet PDUs offer readings for each individual outlet. Switched PDUs allow individual outlets to be turned on/off remotely.

What is the maximum load capacity of this PDU?

The PDU has a maximum load capacity of 11040 VA and 11040 W.

Can I control outlets individually?

Yes, this model is a Switched PDU, allowing for individual remote control (on/off, recycle, lock-out) of each outlet.

What type of outlets does this PDU have?

It features 21 x C13 coupler outlets and 3 x C19 coupler outlets.

What is the input voltage requirement?

The nominal input voltage is 400V.

Does this PDU support environmental monitoring?

Yes, it includes a port for an optional temperature and humidity sensor.

How is this PDU mounted?

It is designed for vertical mounting in a standard server rack, occupying 0U (Zero Rack Unit) width.

Troubleshooting

PDU not powering on

Verify that the main power cord is securely connected to a live, compatible power source. Check the circuit breaker supplying power to the outlet.

Unable to access management interface

Confirm the network cable is properly connected between the PDU and the network. Check the PDU's IP address configuration and ensure it's on the correct network segment. Verify firewall rules if applicable.

Outlet not providing power

Check the status of the specific outlet in the management interface. Ensure it has not been turned off remotely or disabled due to an alarm. Verify the connected device is functioning.

Overload alarm triggered

Review the current draw for each outlet via the management interface. Identify which connected devices are consuming excessive power. Consider load balancing or upgrading power infrastructure if consistently near maximum capacity.

Pros and Cons

Pros

  • Provides granular control over individual outlets, enhancing management flexibility.
  • Offers real-time monitoring of power consumption per outlet, aiding in energy efficiency.
  • Enables remote rebooting of equipment, reducing the need for physical intervention.
  • Supports power sequencing to manage startup loads and prevent overloads.
  • Includes environmental monitoring capabilities with an optional sensor.
  • Built with locking IEC receptacles for secure cable connections.

Cons

  • Requires a 400V nominal input voltage, which may necessitate specific infrastructure.
  • Installation requires rack mounting and appropriate electrical connections.
  • Advanced features may require a learning curve for users unfamiliar with network-based PDU management.
  • Initial setup and configuration for remote access need careful planning.
  • The primary unit is large and takes up vertical space in a rack (ZeroU is a measurement of width, not actual space occupied).

Setup, Compatibility & Care

Setup: This PDU is designed for vertical (0U) rack mounting. Ensure it is securely fastened within the server rack. Connect the main power cord to a compatible power source with the correct voltage (400V nominal input) and amperage (16A maximum). Connect your IT equipment to the C13 and C19 outlets. For remote management, connect the PDU's network port to your network infrastructure.

Compatibility: The PDU features 21 x C13 and 3 x C19 outlets, compatible with standard server and network equipment power cords. It operates with AC input frequencies of 50-60 Hz. Ensure your power distribution system can support the PDU's maximum load capacity of 11040 VA / 11040 W.

Care: Keep the PDU in a clean, dry environment. Regularly check for dust accumulation around ventilation points. When performing maintenance, always ensure the PDU is de-energized. Clean the exterior with a dry or slightly damp cloth; avoid abrasive cleaners. Periodically verify network connections and management interface accessibility.

Price History

DatePrice
Visit shop