IMO RCBO - B6CR1N - 40A - 2P - 30mA - Type A

Best current price£79.51from eBay
Best offers
Shopping.co.uk recommended and popular offers
eBay£79.51Visit shop IMO 40A 2P RCBO 30mA Type A C Curve
Visit shop
Best current price£79.51from eBay
Shopping.co.uk recommended and popular offers
eBay£79.51Visit shop IMO 40A 2P RCBO 30mA Type A C Curve
Visit shop3 offers from £79.51 - £118.79
View price history by clicking the chart icon.
This IMO Residual Current Circuit Breaker with Overload (RCBO) is designed for electricians and homeowners needing robust protection for electrical installations. Its key benefit is safeguarding against earth fault leakage current, overload, and short circuits in a single unit. A caveat is that installation requires professional electrical knowledge.
| Series | B6CR1N |
|---|---|
| Model Part Number | B6CR1N40-30-A |
| Brand | IMO |
An RCBO combines the functions of a Residual Current Device (RCD) and an Overcurrent Protection Device (like a Miniature Circuit Breaker - MCB). It protects against electric shock (earth faults) and against overloads and short circuits.
30mA (milliamps) refers to the residual current sensitivity. The device will trip when it detects a leakage current of 30mA or more to earth, which is generally considered the threshold for causing serious harm to a person.
Type A RCBOs are designed to detect both AC (alternating current) and pulsating DC (direct current) residual currents. This provides protection against a wider range of fault conditions compared to Type AC devices.
No, due to the critical safety functions of an RCBO, it must be installed by a qualified electrician in accordance with all applicable electrical regulations.
An RCD only provides protection against earth leakage faults. An RCBO provides protection against earth leakage faults *and* overcurrents (overloads and short circuits).
Most RCBOs have a built-in test button labelled 'T' or 'Test'. Pressing this button simulates a fault condition and should cause the RCBO to trip. This should be performed regularly (e.g., monthly) as part of electrical maintenance.
'40A' is the current rating, meaning the circuit can handle up to 40 Amperes continuously. '2P' means it is a double-pole device, switching and protecting both the live and neutral conductors.
This indicates a persistent earth fault leakage current, overload, or short circuit in the connected circuit. Disconnect all loads from the circuit and attempt to reset the RCBO. If it holds, reconnect loads one by one to identify the faulty appliance or wiring. If it still trips with no loads connected, consult a qualified electrician.
The RCBO may be faulty or the test button mechanism is not functioning. Do not rely on this RCBO for protection. Replace the unit immediately and have it inspected by a qualified electrician.
This could be due to minor leakage currents from multiple sources, sensitive equipment, or a developing fault. Consult a qualified electrician to investigate potential issues within the wiring or connected appliances.
Setup:
Installation of this RCBO must be performed by a qualified electrician in accordance with local wiring regulations. It requires mounting onto a standard DIN rail within an appropriate electrical enclosure. Ensure the correct terminations for live, neutral, and load are made.
Compatibility:
This 2-pole RCBO is designed for use in standard AC electrical systems. It is compatible with most modern modular electrical distribution boards. Ensure the upstream supply and downstream loads are within the RCBO's rated 40A capacity and voltage limits.
Care:
Regular inspection of the RCBO is recommended as part of general electrical maintenance. Keep the unit clean and free from dust and moisture. Periodically test the device using its built-in test button to ensure the tripping mechanism is functional. Refer to the manufacturer's manual for specific testing frequencies.