Eaton FAZ Circuit Breaker - 6A Curve S




Best current price£16.84from Tameson UK
Best offers
Shopping.co.uk recommended and popular offers
Eaton Industries Faz Circuit Breaker - 278610
Visit shop



Best current price£16.84from Tameson UK
Shopping.co.uk recommended and popular offers
Eaton Industries Faz Circuit Breaker - 278610
Visit shop2 offers from £16.84 - £41.39
View price history by clicking the chart icon.
The Eaton FAZ-S6/1 is a compact, single-pole miniature circuit breaker (MCB) designed for reliable overcurrent protection in electrical installations. Ideal for electricians and system integrators needing a dependable safety device, its primary benefit is robust protection with a 10 kA breaking capacity. A minor caveat is its specific Type A tripping characteristic, which should be matched to the circuit's requirements.
| Series | FAZ |
|---|---|
| Model Part Number | 278610 |
| Brand | Eaton |
A Type S tripping characteristic indicates a delayed response to overcurrents, designed to prevent nuisance tripping on inrush current while still providing protection against sustained overloads and short circuits. It typically has a higher pick-up current for short-duration surges compared to a Type B or C breaker.
The Eaton FAZ-S6/1 has a breaking capacity of 10 kA (kiloamperes), meaning it can safely interrupt fault currents up to 10,000 Amps.
While rated for 240V AC, it will function in a 120V AC system. However, its primary rating is optimized for 230V/240V applications.
To reset the breaker, first identify and resolve the cause of the trip. Then, simply move the operating lever back to the 'ON' position.
The operating temperature range for this circuit breaker is -25 °C to 75 °C (-13 °F to 167 °F).
This circuit breaker is designed for AC (Alternating Current) circuits and is not recommended for DC (Direct Current) applications.
IP20 is an Ingress Protection rating that signifies the device is protected against solid objects greater than 12.5 mm (like fingers) but offers no protection against water or moisture.
Verify the load current does not exceed the 6A rating. Check for potential short circuits or faulty appliances on the protected circuit. Ensure the tripping characteristic (Type S) is appropriate for the connected load.
Confirm the breaker is correctly installed and energized. Check wiring connections. If the issue persists, the breaker may be faulty and requires replacement.
Ensure you are using a standard 35mm top hat DIN rail. The 3-position clip may require a specific sequence for attachment or release; consult installation guides if unsure.
The CPI should clearly indicate the ON/OFF state. If unclear, ensure no obstructions. The breaker may require inspection or replacement if the indicator is internally damaged.
Setup:
Compatibility:
Care: