Caleffi Automatic Filling Unit - 1/2'' - 553140

This Caleffi Automatic Filling Unit features a calcification-resistant internal preset with a pres...

Best current price£88.24from OnBuy.com

One Offer

1 offer from £88.24

View price history by clicking the chart icon.

OnBuy.comCaleffi 553140 Automatic Filling Unit 1/2'' With Manual Cock, Strainer, Check Valve.and Pressure Gauge 8016615016352
Free delivery in 1–3 days
£88.24
Visit shop

Product Information

Full details

This Caleffi Automatic Filling Unit is designed for heating and cooling systems requiring consistent water pressure. Its key benefit is maintaining optimal system pressure automatically, preventing damage and ensuring efficient operation. A potential caveat is the need for periodic checks of the pressure gauge for manual verification. This unit features a calcification-resistant internal preset, an integrated pressure gauge, a manual cock, strainer, and check valve, operating within a pressure range of 0.3 to 4 bar and up to 70°C.

All features

Model Part Number553140
BrandCaleffi

Extended Product Information

FAQs

What is the maximum pressure this unit can handle?

The maximum operating pressure for the Caleffi Automatic Filling Unit is 16 bar, while the adjustable filling pressure range is 0.3 to 4 bar.

Can this unit be used for domestic hot water systems?

This unit is primarily designed for heating and cooling systems. For domestic hot water, a different type of pressure reducing valve might be more appropriate.

How do I adjust the pressure setting?

The pressure is adjusted using a knob on the unit. Rotate the knob to increase or decrease the desired system pressure within the 0.3 to 4 bar range. Refer to the installation manual for specific instructions.

What is the purpose of the check valve?

The check valve prevents water from flowing backward from the heating/cooling system into the main water supply line, which is crucial for system hygiene and integrity.

How often should the strainer be cleaned?

It is recommended to check and clean the strainer periodically, typically during annual system maintenance. The frequency may increase in areas with higher water sediment content.

What is the maximum temperature the unit can withstand?

The maximum operating temperature for this Caleffi Automatic Filling Unit is 70 °C (158 °F).

Is this unit self-priming?

This unit is designed to maintain pressure in a closed system and does not require self-priming in the conventional sense. It relies on the incoming water supply pressure to function.

Troubleshooting

Unit not filling the system

Check if the manual cock is fully open. Ensure the inlet water supply is turned on and has adequate pressure. Verify that the strainer is not clogged.

System pressure is too high or too low

Adjust the pressure setting knob on the unit. Refer to the product manual for correct adjustment procedures. Ensure the set point is within the 0.3-4 bar range.

Leaking from the unit

Check all connections for tightness. Inspect seals and O-rings for damage. If leaking persists from the unit itself, contact a qualified technician.

Pressure gauge not functioning

Ensure the gauge is correctly seated and not damaged. If the gauge is faulty, it may need replacement.

Pros and Cons

Pros

  • Ensures consistent system pressure for optimal performance.
  • Durable construction with calcification-resistant components.
  • Integrated gauge simplifies pressure monitoring.
  • Includes essential components like a strainer and check valve for system protection.
  • Manual shut-off capability for maintenance.

Cons

  • Requires occasional manual verification of the pressure gauge.
  • Maximum operating temperature of 70°C may limit use in some high-temperature applications.
  • Does not include a separate pressure reducing valve for systems requiring very specific pressure settings below the unit's range.
  • Requires a basic understanding of plumbing for installation.

Setup, Compatibility & Care

Setup:

  1. Identify a suitable location on the main water supply line feeding the heating or cooling system.
  2. Ensure the system is depressurized and drained if necessary.
  3. Install the 1/2'' filling unit in the direction of water flow, as indicated on the unit.
  4. Connect the inlet to the main water supply and the outlet to the heating/cooling system.
  5. Open the manual cock and adjust the pressure setting using the adjustment knob to the desired level (0.3-4 bar).
  6. Open the manual cock fully after confirming correct pressure.

Compatibility:

  • Suitable for closed heating and cooling systems.
  • Maximum operating pressure: 16 bar.
  • Maximum operating temperature: 70 °C.
  • Connection size: 1/2'' thread.

Care:

  • Periodically check the pressure gauge to ensure the system pressure is maintained.
  • The internal strainer should be cleaned periodically to prevent blockages. Access may require shutting off water supply and carefully disassembling the lower part of the unit. Consult a professional if unsure.
  • Avoid using abrasive cleaners; a damp cloth is sufficient for the exterior.