Product Information

Full details

This Grant Flue Extension (model GX950/90B) is designed for installers needing to extend or modify existing high-level and vertical flue systems. Its modular form allows for flexible configurations, and its high-grade stainless steel construction ensures durability. A key benefit is its adaptability to various installation scenarios. However, users should be aware that it requires precise measurement and cutting for optimal integration into existing systems.

All features

Model Part NumberGX950/90B
BrandGrant

Extended Product Information

FAQs

What is the primary purpose of the Grant Flue Extension GX950/90B?

Its primary purpose is to extend the length of existing Grant EZ-Fit External high-level and vertical flue systems, allowing for more flexible installation routing.

What material is the flue extension made from?

It is manufactured from high-grade stainless steel.

Can this flue extension be used with any boiler?

This extension is specifically designed for Grant EZ-Fit External flue systems. Compatibility with your specific Grant boiler model should be confirmed.

Do I need to cut the flue extension?

Yes, the modular design allows for cutting to achieve the precise length required for your installation. Ensure cuts are clean and made with appropriate tools.

How should I clean the flue extension?

The exterior of the flue system can be cleaned with a damp cloth. Avoid abrasive cleaners that could damage the stainless steel finish.

What is the length of this flue extension?

This specific model, GX950/90B, provides an additional length of 950mm.

Is this a complete flue system?

No, this is an extension designed to be integrated with an existing Grant EZ-Fit flue system, not a standalone system.

Troubleshooting

Difficulty connecting flue sections

Ensure both sections are clean, free from debris, and aligned correctly. Verify you are using the correct Grant-approved fittings.

Apparent flue gas leaks

Immediately shut down the heating system and check all connection points. Re-seal any compromised joints with appropriate sealant. If the issue persists, contact a qualified installer.

Corrosion or damage to the stainless steel

Inspect the affected area. Minor surface marks may not impact performance, but significant corrosion or holes require replacement of the affected section.

Pros and Cons

Pros

  • Adaptable to a wide range of installation scenarios due to its modular design.
  • Constructed from durable, high-grade stainless steel for extended lifespan.
  • Provides necessary length for optimizing flue system placement.
  • Suitable for both horizontal and vertical flue runs.

Cons

  • Requires precise installation and potentially custom cutting for a perfect fit.
  • Not a standalone flue system; designed to extend existing setups.
  • Installation may require specialized tools and knowledge of flue systems.

Setup, Compatibility & Care

Setup:

  1. Measure and plan the required flue path carefully.
  2. Ensure the existing flue system is compatible with extensions.
  3. Cut the extension and existing flue components to the precise lengths needed.
  4. Connect the extension using appropriate Grant-approved fittings and sealants.
  5. Ensure all connections are secure and airtight to prevent leaks.

Compatibility:

  • Designed for use with Grant EZ-Fit External high level and vertical flue systems.
  • Verify compatibility with your specific Grant boiler model before installation.

Care:

  • Regular visual inspection of the flue system for any signs of damage or corrosion.
  • Clean the exterior of the flue system with a damp cloth as needed.
  • Refer to your boiler's manual for specific flue system maintenance requirements.