Schneider Electric TeSys U Auxiliary Contact Block - LUA1C20

TeSys U signaling auxiliary contact block designed for TeSys U motor starters. Features one NO con...

Best current price£10.98from Tameson UK

All Offers

6 offers from £10.98 - £47.41

View price history by clicking the chart icon.

Tameson UKSchneider Electric Green Tesys U Auxiliary Contact Block - Lua1c20
Free delivery in 1–3 days
£10.98
Visit shop
eBay2Z additional contacts front mounting LUA1C20 TeSys U
£13.20 delivery
£41.87
Visit shop

Used Offers

2 offers from £16.36

View price history by clicking the chart icon.

eBayTelemecanique Hilfskontakt LUA1C20 Auxiliary Contact 036730 1S+1S
£28.84 delivery
£16.36
Visit shop

Product Information

Full details

The Schneider Electric LUA1C20 is a signaling auxiliary contact block designed for TeSys U motor starters. It provides essential status monitoring for open/closed states and trip conditions, enhancing system visibility. A key benefit is its direct integration with the power base for a streamlined setup. However, it offers only normally open (NO) contacts, which may limit certain advanced control configurations.

All features

SeriesU-Line
Model Part NumberLUA1C20
BrandSchneider Electric

Extended Product Information

FAQs

What is the primary function of the LUA1C20?

The LUA1C20 provides signaling for TeSys U motor starters, indicating the open/closed status (OF) and trip status (SD) via two normally open contacts.

How many normally open (NO) and normally closed (NC) contacts does it have?

It features two normally open (NO) contacts and no normally closed (NC) contacts.

What is the electrical rating of the contacts?

The contacts are rated up to 5A at 250V AC/DC.

How is the LUA1C20 mounted?

It mounts directly onto the front of a TeSys U power base using a simple clip-on mechanism.

Does this contact block work with any motor starter?

No, it is specifically designed for Schneider Electric TeSys U motor starters.

What does 'OF contact' and 'SD contact' mean?

OF stands for Open/Closed Status, indicating if the associated circuit is open or closed. SD stands for Signaling Device, typically indicating a trip or fault condition.

Is this product compliant with environmental regulations?

Yes, it is compliant with Green Premium ecolabel standards, including RoHS and REACh.

Troubleshooting

Contact block not detected by control system

Verify that the contact block is securely clipped to the power base. Ensure wiring to the OF and SD terminals is correct and tight. Check the corresponding input channels on your PLC or control system.

Inconsistent status signaling (OF or SD)

Inspect the wiring for any loose connections or breaks. Ensure the TeSys U starter itself is functioning correctly. Clean the contacts on the power base and the auxiliary block if there is visible contamination.

Difficulty mounting the block

Ensure you are using a compatible TeSys U power base. Make sure no obstructions are preventing the block from seating properly. Apply firm, even pressure during mounting.

Pros and Cons

Pros

  • Provides critical open/closed and trip status monitoring.
  • Easy direct mounting onto TeSys U power bases.
  • Robust electrical ratings for versatile use.
  • Environmentally compliant with Green Premium standards.

Cons

  • Only provides Normally Open (NO) contacts.
  • Requires a compatible TeSys U system for integration.
  • Specific to TeSys U motor starters, limiting broader application.

Setup, Compatibility & Care

Setup: The LUA1C20 is designed to clip directly onto the front of a TeSys U power base. Ensure the power base is properly installed and de-energized before attaching the auxiliary contact block. Align the block with the mounting points on the power base and press firmly until it clicks into place. Wire the OF and SD contacts according to your control schematic using the screw terminals.

Compatibility: This auxiliary contact block is specifically designed for use with Schneider Electric TeSys U motor starters. It is not compatible with other starter types or systems.

Care: Keep the contact block clean and free from dust and debris. Periodically check wiring connections for tightness. Avoid exposure to excessive moisture or corrosive environments.