Solenoid Valve - G2'' NC Brass NBR 0.2-16bar/3-232psi 24VAC 6281 253157

Burkert 2/2 way solenoid valve (type 6281) with G 2 inch threads and a 24 V AC coil. The circuit f...

Best current price£315.08from Tameson UK

All Offers

10 offers from £315.08 - £332.21

View price history by clicking the chart icon.

Tameson UKBurkert Solenoid Valve G2'' Nc Brass Nbr 0.2-16Bar/3-232Psi 230Vac 6281 221867
Free delivery in 1–3 days
£315.08
Visit shop

Product Information

Full details

The Burkert 6281 solenoid valve is designed for controlling fluid flow in industrial applications. It is ideal for users needing a reliable, indirectly operating valve with brass construction and NBR sealing. A key benefit is its robust performance across a wide pressure range. However, a DIN connector is not included and must be sourced separately.

All features

Model Part Number253157
BrandBurkert

Extended Product Information

FAQs

What is the purpose of the differential pressure requirement?

The 6281 is an indirectly operated valve. It requires a small pressure difference between the inlet and outlet ports (at least 0.2 bar) to help lift the diaphragm and open the valve when the solenoid coil is energized.

Can this valve be used with aggressive chemicals?

The NBR seals offer good resistance to many substances, but they are not suitable for all aggressive chemicals. Always verify the compatibility of NBR with your specific media at the operating temperature. For more aggressive media, consider variants with FKM or EPDM seals.

What type of connector is needed?

A DIN connector is required to connect the electrical supply to the solenoid coil. This connector is not included with the valve and must be purchased separately.

What is the Kv-value and why is it important?

The Kv-value (40 m³/h) indicates the flow rate of water in cubic meters per hour that will pass through the valve with a pressure drop of 1 bar. A higher Kv-value signifies greater flow capacity.

What is the maximum temperature the valve can handle?

The valve is designed to handle media temperatures up to 80 °C (176 °F).

Is this valve suitable for vacuum applications?

No, this valve is designed for positive pressure applications ranging from 0.2 bar upwards. It is not suitable for vacuum service.

Can I use this valve with 24V DC power?

No, this specific model (253157) is designed for 24V AC coil operation. Using DC voltage will not operate the valve correctly and may damage the coil.

Troubleshooting

Valve does not open when energized

Ensure the correct 24V AC voltage is supplied to the coil. Verify that a DIN connector is properly attached and functioning. Check that the system's differential pressure is above the minimum requirement of 0.2 bar. Confirm the coil is not faulty.

Valve does not close when de-energized

Check for any debris lodged in the valve seat preventing closure. Ensure the system pressure has dropped sufficiently. Verify the coil is completely de-energized.

Leaking from threaded connections

Ensure threads are properly sealed with appropriate tape or sealant. Check that connections are tightened securely but not overtightened. Inspect threads for damage.

Intermittent operation

Check electrical connections for looseness or corrosion. Ensure consistent voltage supply. Verify that the media temperature and pressure are within the specified operating range.

Pros and Cons

Pros

  • Robust brass construction for durability.
  • Suitable for a broad operating pressure range.
  • High flow capacity due to a large orifice and Kv-value.
  • Reliable sealing with NBR material.
  • Indirect operation simplifies system design in some scenarios.

Cons

  • Requires a minimum differential pressure to function.
  • DIN connector is not included and must be purchased separately.
  • Maximum media temperature limited to 80 °C (176 °F).
  • NBR sealing may not be suitable for all chemical applications.

Setup, Compatibility & Care

Setup:

  1. Mounting: Install the valve in the desired position within the pipeline. Ensure the flow direction arrow on the valve body aligns with the intended fluid flow.
  2. Electrical Connection: Connect the 24V AC coil using appropriate wiring. *Note: A DIN connector is required but not supplied with the valve.* Ensure the connector and wiring comply with safety standards for the operating environment.
  3. System Integration: Connect the G 2-inch threaded ports to your piping system using suitable thread sealant or tape to prevent leaks.
  4. Differential Pressure: Confirm that the system's minimum differential pressure (0.2 bar) is met for the valve to operate correctly when energized.

Compatibility:

  • Voltage: Designed for 24V AC operation.
  • Thread Size: G 2 inch connections.
  • Sealing Material: NBR seals are compatible with water, air, oils, and many non-aggressive chemicals. Verify compatibility with your specific media.
  • Media Temperature: Suitable for media up to 80 °C (176 °F).
  • Pressure: Compatible with systems operating between 0.2 and 16 bar.

Care:

  • Cleaning: Periodically inspect the valve for external debris. Clean with a damp cloth if necessary. Avoid harsh solvents.
  • Maintenance: Ensure electrical connections remain clean and secure. Check for leaks around the threaded connections.
  • Filter: If used with fluids containing particulates, consider installing a strainer upstream of the valve to prevent clogging.
  • Storage: Store in a clean, dry environment before installation.