ABB Busch-Jaeger I-Bus KNX Application Controller - GHQ6310080R0111

This ABB Busch-Jaeger I-Bus KNX Application Controller is designed to solve a varied range of proj...

Best current price£152.43from Tameson UK

One Offer

1 offer from £152.43

View price history by clicking the chart icon.

Tameson UKAbb Busch-Jaeger I-Bus Knx Application Controller Bus System - Ghq6310080r0111
Free delivery in 1–3 days
£152.43
Visit shop

Used Offer

1 offer from £307.43

View price history by clicking the chart icon.

Product Information

Full details

This ABB Busch-Jaeger I-Bus KNX Application Controller (GHQ6310080R0111) is for KNX system integrators and smart home installers seeking to implement complex, project-specific control logic. Its key benefit is the ability to execute up to three functions simultaneously, offering powerful customization for automation tasks. A potential caveat is its specialized nature, requiring KNX system knowledge for effective implementation. This controller integrates various functions like logic gates, time delays, and scene management onto the KNX bus.

All features

BrandABB

Extended Product Information

FAQs

What is the primary purpose of the ABB Busch-Jaeger I-Bus KNX Application Controller?

Its primary purpose is to execute complex, project-specific control tasks and automation logic within a KNX system, allowing for the implementation of multiple functions (up to three) simultaneously on a single device.

Can this controller be used in non-KNX systems?

No, this controller is specifically designed for and compatible only with KNX bus systems.

What types of functions can this controller perform?

It can perform a wide range of functions including logic operations (gates, filters), time delays, value manipulation (multipliers, min/max detectors), comparators, scene control, increment/decrement operations, and staircase lighting control.

How is the controller programmed?

The controller is programmed using the ETS (Engineering Tool Software) provided by KNX, allowing for detailed configuration of its functions and logic.

What are the physical dimensions of the controller?

The dimensions are approximately 3.54 inches (length) x 1.41 inches (width) x 2.51 inches (height).

Does it require a separate power supply?

Yes, like all KNX devices, it requires a KNX bus power supply to operate.

Is it suitable for beginners in home automation?

Due to its advanced capabilities and the need for KNX programming knowledge, it is best suited for experienced installers and integrators rather than beginners.

Troubleshooting

Controller not recognized on KNX bus

Verify KNX bus connections are secure and correctly wired. Ensure the KNX power supply is active and stable. Check device address and group address configuration in ETS.

Functions not executing as programmed

Review the logic and parameter settings within ETS for the specific functions. Ensure all input signals are correctly assigned and that there are no conflicting rules. Verify the device has the correct firmware version.

Overheating or intermittent operation

Ensure the controller is installed in an area with sufficient airflow and is not enclosed in a manner that restricts heat dissipation. Check that the ambient temperature is within the device's operating specifications.

KNX bus errors reported by other devices

Temporarily disconnect the application controller from the bus to see if the errors cease. If they do, re-introduce the controller and check its configuration for potential bus load issues or incorrect addressing.

Pros and Cons

Pros

  • High degree of customization for complex automation scenarios.
  • Reduces the need for multiple devices by combining functions.
  • Reliable integration with existing KNX infrastructure.
  • Facilitates advanced logic and scene management.
  • Space-saving design with DIN-rail mounting.

Cons

  • Requires in-depth knowledge of KNX programming and logic.
  • Not suitable for simple, basic automation tasks.
  • Configuration can be complex for novice users.
  • Limited to KNX bus systems.

Setup, Compatibility & Care

Setup:

  1. Mount the controller onto a standard DIN-rail within a KNX-compatible electrical enclosure.
  2. Connect the device to the KNX bus line using appropriate cabling.
  3. Utilize ETS (Engineering Tool Software) for programming the desired functions, logic, and parameters according to project requirements.

Compatibility:

  • Fully compatible with KNX bus systems.
  • Designed for EIB installations.
  • Requires a KNX power supply.

Care:

  • The controller requires no regular maintenance. Ensure adequate ventilation within the enclosure to prevent overheating.
  • Keep the device free from dust and moisture. If cleaning is necessary, use a dry or slightly damp cloth. Do not use solvents or abrasive cleaners.

Price History

DatePrice
Visit shop