Catnic External Solid Wall Single Leaf Angle Lintel - 1500mm ANG1500

The Catnic Angle lintel system is designed for thin joint wall construction, accommodating all cav...

Best current price£33.68from Materials Market Trading UK Ltd

All Offers

25 offers from £33.68 - £439.44

View price history by clicking the chart icon.

Materials Market Trading UK LtdCatnic Ang Single Leaf Angle Lintel 900Mm Silver
Free delivery in 1–3 days
£33.68
Visit shop
Brick SuperstoreCatnic Black Bsd100 Standard Duty Box Steel Lintel - 750Mm
£108.00 delivery
£40.75
Visit shop
Travis PerkinsCatnic External Solid Wall Single Leaf Steel Angle Lintel, 900mm
£30.00 delivery
£56.70
Visit shop

Product Information

Full details

This guide is for builders and construction professionals utilizing thin joint wall construction who need a reliable, thermally efficient lintel solution. The Catnic Angle Lintel provides robust support for openings in external solid walls, reducing thermal bridging and simplifying installation. However, users must ensure appropriate propping and lateral restraint during the construction phase for optimal performance and safety.

All features

Model Part NumberANG1500
BrandCatnic

Extended Product Information

FAQs

What is 'thin joint wall construction'?

Thin joint wall construction is a modern masonry technique that uses thin layers of mortar (typically 2-3mm) instead of traditional thick mortar beds. It often utilizes specially designed blocks and reduces drying times, improving thermal performance and construction speed.

Can this lintel be used with different wall thicknesses?

Yes, the Catnic Angle Lintel system is designed to accommodate the requirements of all possible cavity widths, providing versatility for various wall thicknesses and designs.

What does 'thermal bridging' mean and how does this lintel help?

Thermal bridging occurs when heat can escape or enter a building more easily through certain materials or construction elements, like lintels. This lintel is designed to help reduce thermal bridging at window heads, contributing to better insulation and energy efficiency.

What is 'Duplex Corrosion Protection'?

Duplex Corrosion Protection refers to a dual-layer protective coating system. This typically involves galvanization combined with a powder coating or paint finish, providing superior resistance against rust and corrosion compared to single-layer protection.

Is propping necessary during installation?

Yes, it is crucial. The lintel must be suitably propped and laterally restrained during construction until the mortar has fully cured and the masonry above has gained sufficient strength to be self-supporting. Failure to do so can lead to instability and compromise structural integrity.

How do I choose the correct lintel length?

Measure the width of the opening accurately. You then need to add a minimum of 150mm bearing to each side. So, for an opening of length 'X', the lintel length should be at least 'X + 300mm'. Select the closest standard length available from the manufacturer.

Can this lintel be used for internal walls?

Yes, the product description states that thin joint can be used on both external cavity and internal partition walls, as well as party wall construction, implying this lintel is suitable for internal applications within thin joint systems.

Troubleshooting

Lintel appears unstable or sags during construction.

This is typically due to insufficient propping or lateral restraint. Ensure the lintel is adequately propped along its length and laterally restrained according to manufacturer specifications until the masonry above has fully cured and is self-supporting.

Concern about long-term corrosion.

The lintel is equipped with Duplex Corrosion Protection for enhanced durability. As long as the protective coating remains intact and undamaged after installation, specific ongoing anti-corrosion care is generally not required under normal conditions. Inspect for damage prior to installation.

Lintel does not fit the opening correctly.

Lintels are available in standard incremental lengths. Always measure the opening accurately before ordering. Ensure the lintel selected allows for a minimum of 150mm bearing at each end of the opening.

Unsure if the lintel is suitable for a specific load.

This lintel is designed for standard duty loading applications. For heavier or specific structural loads, consult with a structural engineer to determine if this lintel is appropriate or if an alternative heavy-duty solution is required.

Pros and Cons

Pros

  • Optimized for modern thin joint construction methods.
  • Versatile application across various cavity widths.
  • Enhances building energy efficiency by reducing thermal bridging.
  • Provides superior long-term durability due to Duplex Corrosion Protection.
  • Simplifies specification with standard duty loading.
  • Range of standard lengths facilitates easier planning and installation.

Cons

  • Requires temporary propping and lateral restraint during construction.
  • Limited to standard duty loading applications; not for heavy-duty structural requirements.
  • Length options are in fixed increments, requiring accurate measurement.

Setup1. Preparation: Ensure the opening is correctly sized for the selected 1500mm lintel. The lintel should have a minimum bearing of 150mm at each end on sound masonry.2. Placement: Position the lintel accurately above the opening.3. Propping and Restraint: Crucially, the lintel *must* be suitably propped along its length and laterally restrained during the construction process. This support should remain in place until the mortar has fully cured and the wall above has reached sufficient strength to be self-supporting. Follow manufacturer guidelines for propping distances and durations.4. Masonry Laying: Begin laying masonry over the lintel, ensuring full mortar beds and proper coursing.### CompatibilityThis Catnic Angle Lintel is specifically designed for:- Thin Joint Wall Construction: Ideal for modern construction methods utilizing thin joint mortar systems.- External Solid Walls: Suitable for supporting masonry above openings in external solid walls.- Single Leaf Walls: Designed for single leaf wall configurations.- Cavity Widths: Accommodates all possible cavity widths, offering broad applicability.### CareDue to its Duplex Corrosion Protection, the Catnic Angle Lintel requires minimal ongoing care after installation. During transportation, storage, and installation, protect the lintel from excessive damage to the protective coating. Any significant scratches or damage to the coating should be addressed before final installation to maintain its corrosion resistance. Regular inspection during building maintenance is recommended to ensure its long-term integrity.