Phoenix Contact Redundant DIN Rail Diode Module - 2907719

Industrial DIN rail diode module offering dual 20A or single 40A output configuration with univers...

Best current price£125.86from Tameson UK

One Offer

1 offer from £125.86

View price history by clicking the chart icon.

Tameson UKPhoenix Contact Redundant Din Rail Diode Module 12-24V Dc - 2907719
Free delivery in 1–3 days
£125.86
Visit shop

Used Offer

1 offer from £87.19

View price history by clicking the chart icon.

eBayPHOENIX CONTACT 2907719 ; QUINT4-DIODE/12-24DC/2X20/1X40 REDUNDANCY MODULE New
£27.00 delivery
£87.19
Visit shop

Product Information

Full details

This Phoenix Contact DIN rail diode module (MPN: 2907719) is designed for industrial applications requiring reliable power redundancy. It offers users a flexible dual 20A or single 40A output configuration to protect critical loads from power supply failures. A key benefit is its high 97% efficiency, minimizing energy waste. One caveat is the IP20 protection, meaning it's suitable for dry, controlled environments only.

All features

Model Part Number2907719
BrandPhoenix Contact

Extended Product Information

FAQs

What is the maximum input voltage supported?

The module supports an input voltage range of 10-30V DC.

Can this module be used in dusty environments?

The module has an IP20 protection rating, which means it is protected against solid objects larger than 12.5mm but offers no protection against moisture or fine dust. It is best suited for clean, controlled industrial environments.

How do I configure it for single 40A output?

To configure for a single 40A output, you typically parallel the input terminals from your power supplies and connect them to the module's input, and then connect the paralleled outputs to your load. Always refer to the official manual for precise wiring diagrams.

What is the operating temperature range?

The module operates reliably within a wide temperature range of -40°C to 70°C.

What is the width of the module for DIN rail mounting?

The module has a compact width of 50mm, designed for standard 35mm DIN rail mounting.

Does the module provide active current sharing between power supplies?

This module is a diode module, providing passive redundancy by preventing reverse current flow. It does not actively manage current sharing between power supplies; that functionality is typically found in more advanced redundancy modules.

What does 'universal redundancy' mean in this context?

It means the module can be used to create a redundant power system for various applications, allowing either a dual 20A configuration or a single 40A configuration to prevent downtime from a single power supply failure.

Troubleshooting

No output voltage when inputs are powered

Verify input voltage is within the 10-30V DC range. Check for correct polarity on input connections. Ensure module is properly seated on DIN rail. Verify load connections are secure.

Output voltage drops under load

Check if the load current exceeds the module's rating (2x20A or 1x40A). Ensure input power supplies can provide sufficient current. Verify wiring gauge is appropriate for the current.

Module overheats

Ensure adequate ventilation around the module. Verify load current is within specifications. Check that input power supplies are stable and within range.

Module fails to provide redundancy

Confirm both input power supplies are operational and within the specified voltage range. Check that inputs are correctly wired to the module. Ensure the load is connected to the output terminals.

Pros and Cons

Pros

  • Enhances power supply reliability through redundancy.
  • Efficient operation minimizes energy waste and heat.
  • Flexible configuration options adapt to different load needs.
  • Robust construction suitable for industrial environments.
  • Space-saving DIN rail mount design.

Cons

  • IP20 protection limits use to dry, controlled environments.
  • Requires separate power supplies for redundancy.
  • Not suitable for applications requiring higher ingress protection (e.g., IP65).

Setup, Compatibility & Care

Setup: Mount the module securely onto a standard 35mm DIN rail. Connect the input power terminals (DC 10-30V) from your power supplies. Connect the output terminals to your load(s). Ensure correct polarity is observed. The module can be configured for dual 20A output by connecting separate inputs to their respective outputs, or for a single 40A output by paralleling inputs and outputs (refer to manual for specific wiring diagrams).

Compatibility: Compatible with DC power supplies in the 10-30V range. Suitable for industrial control cabinets and power distribution systems. Not recommended for environments with excessive dust, moisture, or corrosive substances due to its IP20 rating.

Care: Keep the module clean and free from dust and debris. Ensure adequate ventilation around the module. Periodically check screw terminal connections for tightness. No user-serviceable parts inside; consult a qualified technician for repairs.

Price History

DatePrice
Visit shop