Automatic Bypass Valve suitable for all heating systems up to 10 bar static pressure where a boile...Automatic Bypass Valve suitable for all heating systems up to 10 bar static pressure where a boiler bypass is required or radiator thermostats are fitted. It provides a simple method of ensuring adequate flow through boilers which require a bypass as well as reducing system noise. In systems fitted with radiator thermostats, the valve opens automatically as the TRVs or zone valves close down and the resistance of the system starts to exceed the preset pressure limit. Unique and simple adjustment mechanism High capacity flow up to 83 litres per minute Wide differential pressure range 0.1 bar to 0.5 bar 22mm Compression fittings for ease of installation Reduces system noise and maintains an even system pressure Ensures constant flow through boiler Lockable set pressure prevents inadvertent adjustment. A PlumbRight automatic bypass valve is designed for all heating systems up to 10 bar static pressure where a boiler bypass is required or radiator thermostats are fitted. It provides a simple method of ensuring adequate flow through boilers that require a bypass as well as reducing system noise. In systems fitted with radiator thermostats, the valve opens automatically as the thermostatic radiator valve or zone valves close down and the resistance of the system starts to exceed the preset pressure limit.
Plumbright 22mm Auto By-Pass Valve Angled code 931363(M974)Free delivery in 1–3 days£13.99Visit shop →
Product Information
Full details
This guide helps homeowners and heating engineers understand and effectively utilize the Plumbright Automatic Bypass Valve (22mm Angled). Designed for heating systems requiring a boiler bypass or those fitted with radiator thermostats, this valve ensures optimal system flow and reduces noise. A key benefit is its automatic operation, reacting to system pressure changes. Note that proper installation is crucial for optimal performance.
All features
Model Part Number
81004010-BSS
Brand
Plumbright
Extended Product Information
FAQs
What is the purpose of an automatic bypass valve?
The valve ensures adequate flow through the boiler, especially when thermostatic radiator valves (TRVs) close, preventing the boiler from overheating and reducing system noise.
Where should the bypass valve be installed?
It should be installed in the bypass loop, typically between the flow and return pipes of the heating system, before the boiler.
What size are the fittings on the Plumbright Automatic Bypass Valve?
The valve has 22mm compression fittings for easy installation.
Can I adjust the pressure setting on the valve?
The set pressure is generally preset and lockable. Avoid adjusting it unless absolutely necessary. Check the manufacturer's guidelines.
What should I do if the valve is making noise?
Check the valve setting and system pressure. Look for any blockages in the system that may be causing the noise.
Is the Plumbright Automatic Bypass Valve suitable for all heating systems?
Yes, it is suitable for all heating systems up to 10 bar static pressure.
How often should I inspect the valve?
Regularly inspect the valve for leaks or unusual noises to ensure it is functioning correctly.
What is the warranty period?
Warranty information is not available in the provided product details. Please consult the product documentation or the manufacturer.
Troubleshooting
System noise or whistling sounds.
Check the bypass valve setting. Ensure it's within the specified pressure range (0.1 to 0.5 bar). Also, check for any blockages in the system.
Boiler cutting out or overheating.
Verify the bypass valve is opening when TRVs or zone valves close. Check for blockages or restrictions in the bypass loop.
Poor radiator heating.
Check system pressure and ensure the bypass valve is not excessively open, preventing adequate flow to radiators. Inspect the valves on the radiators.
Pros and Cons
Pros
Ensures adequate flow through boilers that require a bypass.
Reduces system noise.
Maintains even system pressure.
Easy to install with compression fittings.
Automatic operation simplifies system management.
Cons
Requires proper installation for optimal performance.
May require occasional inspection to ensure proper function.
Specific pressure range limitations (0.1 to 0.5 bar).
Setup, Compatibility & Care
Installation: The valve should be installed in the bypass loop, typically between the flow and return pipes of the heating system, before the boiler. Use the 22mm compression fittings provided.
Compatibility: Compatible with all heating systems up to 10 bar static pressure. Ensure the system is drained and depressurized before installation.
Pressure Settings: The valve is preset. Avoid adjusting the set pressure unless necessary.
Care: Regularly inspect the valve for leaks or unusual noises. Ensure the system is flushed and clean during installation to prevent debris from affecting the valve's operation.
Important: Always refer to the manufacturer's instructions for detailed guidance. If you are not familiar with plumbing work, it's recommended to consult a qualified heating engineer for installation.