Schneider Electric Acti 9 iCT Contactor - 25A - 2NO+2NC - A9C20838

The Schneider Electric Acti 9 iCT Contactor, model A9C20838, is a high-performance 4-pole modular ...

Best current price£110.89from eBay

All Offers

3 offers from £110.89 - £140.52

View price history by clicking the chart icon.

eBaySchneider iCT50-25-22-230 Modular Contactor 25A 2NO+2NC 220/240 VAC A9C20838
£13.20 delivery
£110.89
Visit shop

Product Information

Full details

The Schneider Electric Acti 9 iCT Contactor (A9C20838) is an essential component for electrical professionals and facility managers looking to manage power circuits reliably within residential or commercial distribution boards. This 25A 4-pole modular contactor excels at controlling high-demand loads like lighting and heating systems, offering the versatility of 2 Normally Open (NO) and 2 Normally Closed (NC) contacts. While its robust design provides long-term dependability in varied environments, users should note that as a 230-240V AC device, it requires careful circuit planning and professional electrical knowledge for safe installation.

All features

SeriesiCT
Model Part NumberA9C20838
BrandSchneider Electric

Extended Product Information

FAQs

Can this contactor be used in an outdoor environment?

It is not IP-rated for outdoor exposure and must be installed within a suitable weather-proof electrical enclosure.

What is the primary function of the 2NC contacts?

The Normally Closed (NC) contacts are typically used for fail-safe applications where the circuit must remain closed until the contactor is energized.

Is this device compatible with standard DIN rails?

Yes, it is designed for standard DIN rail mounting found in most modern residential and commercial distribution boards.

What happens if the operating temperature exceeds 60°C?

Operating outside the specified range may lead to premature component degradation or failure; ensure adequate ventilation in the distribution cabinet.

Does this model support manual override?

This specific iCT model is intended for automatic control via the electrical signal to the coil rather than manual switching.

Troubleshooting

Contactor fails to engage or 'chatter' occurs

Verify the control circuit voltage is consistently between 230-240V AC and check for loose control wiring connections.

Overheating terminals

Inspect terminal screws for proper tightness and ensure the connected load does not exceed the rated 25A capacity.

Device is not switching the load

Use a multimeter to verify continuity across the contacts and ensure the control coil is receiving the correct voltage signal.

Pros and Cons

Pros

  • Versatile contact configuration (2NO+2NC)
  • Compact modular design saves space on the DIN rail
  • High-quality, reliable construction for frequent switching
  • Suitable for a wide range of temperatures

Cons

  • Requires professional electrical installation
  • Limited to 230-240V AC systems
  • Not suitable for DC load switching applications

Setup, Compatibility & Care

Installation must be performed by a qualified electrician in accordance with local electrical regulations. Mount the device onto a standard symmetrical DIN rail. Ensure all terminal connections are tightened to the recommended torque specifications to prevent overheating. When wiring the contacts, double-check the NO and NC labels to ensure your circuit logic operates as intended. Maintenance involves periodic inspections for loose terminal screws and checking for any debris or moisture inside the distribution board. The device does not require lubrication and should be kept in a dry, ventilated environment.