TOWER 22mm Valve Mid Position 3 Port Motorised Central Heating Control - VAL322MP

TOWER Inline 22mm Central Heating 3 Port Mid-Position Valve Brand new, genuine original Tower 3 p...

Best current price£33.90from eBay

All Offers

5 offers from £33.90 - £74.72

View price history by clicking the chart icon.

eBayTower Flue Components VAL322MP 3 Port Mid-Position Valve 22 mm
Free delivery in 1–3 days
£33.90
Visit shop
OnBuy.comTower 22Mm 3 Port Mid Position Motorised Valve 5 Wire Replaces Honeywell V4073a 5028415001035
Free delivery in 1–3 days
£74.72
Visit shop

Product Information

Full details

This TOWER 22mm 3 Port Mid-Position Valve (VAL322MP) is designed for homeowners with fully pumped central heating systems seeking precise control over hot water and heating zones. Its key benefit is the ability to direct water flow independently to heating, hot water, or both simultaneously, optimizing comfort and energy efficiency. A potential caveat is its requirement for specific system wiring and compatible thermostats/programmers to function correctly. This valve offers reliable spring return operation and standard 230V AC switched output.

All features

Model Part NumberVAL322MP
BrandTower Flue Components

Extended Product Information

FAQs

What type of heating system is this valve suitable for?

This valve is designed for fully pumped central heating systems.

What is the pipe connection size?

The valve features 22mm compression fittings.

Does this valve come with a power cable?

Yes, it includes a 1-meter cable.

Can I manually operate the valve?

Yes, it features a manual override lever for manual positioning.

What is the operating temperature range?

The operating temperature range is +5 to +88°C.

How do I know if the valve is working?

The valve has an LED indicator that provides visual confirmation of its operational status.

What components are needed in conjunction with this valve?

For full control, it requires a compatible room thermostat, cylinder thermostat, and programmer.

Troubleshooting

Valve not switching between positions

Check the 230V AC power supply to the valve. Verify wiring connections to the programmer, room thermostat, and cylinder thermostat are correct and secure. Ensure the system is calling for heat or hot water.

Water leaks from connections

Ensure the 22mm compression fittings are tightened correctly. If leaks persist, the fitting may need to be re-made or the valve may need replacement.

No hot water or heating

Confirm that the system's programmer and thermostats are set correctly. Check that the valve is receiving power and that the actuator is moving. If the valve is stuck, attempt to use the manual override lever.

Valve making unusual noises

Some noise during operation is normal. Loud grinding or clicking may indicate an obstruction or a failing actuator. Check for any external blockages or signs of damage.

Pros and Cons

Pros

  • Provides flexible control over heating and hot water demand.
  • Energy efficient by allowing independent zone operation.
  • Spring return mechanism enhances reliability.
  • Easy to install with standard 22mm compression fittings.
  • Clear LED status indicator for operational feedback.

Cons

  • Requires a fully pumped central heating system.
  • Needs compatible room thermostat, cylinder thermostat, and programmer for full functionality.
  • Installation may require electrical knowledge for wiring.
  • Limited to 22mm pipe sizes.

Setup, Compatibility & Care

Setup: This valve is designed for fully pumped central heating systems. Ensure power is isolated before beginning installation. The valve connects to the heating and hot water pipework using the 22mm compression fittings. Wiring should be carried out according to the system's specific requirements, connecting to a compatible programmer, room thermostat, and cylinder thermostat. The valve requires a 230V AC power supply.

Compatibility: Compatible with standard 230V AC central heating control systems. It requires the presence of a system pump and must be wired with an appropriate programmer, room thermostat, and cylinder thermostat.

Care: Regularly check for leaks around the compression fittings. The external casing can be wiped clean with a dry or slightly damp cloth. Avoid using abrasive cleaners. Periodically, verify that the manual lever operates smoothly. Ensure the area around the valve is free from dust and debris to prevent internal mechanism issues.