Eaton Logic Module - EASY-E4-UC-12RC1



Best current price£289.86from Blueperry agriculture (UK)
Best offers
Shopping.co.uk recommended and popular offers
Eaton Basic Device Easye4uc12rc1
Visit shop


Best current price£289.86from Blueperry agriculture (UK)
Shopping.co.uk recommended and popular offers
Eaton Basic Device Easye4uc12rc1
Visit shop1 offer from £289.86
View price history by clicking the chart icon.
The Eaton EASY-E4-UC-12RC1 is a compact, expandable PLC controller designed for small to medium-sized automation tasks, particularly in building automation and machine control. Its key benefit lies in its flexibility and integrated display, allowing for efficient monitoring and control. A potential caveat is its limited number of analog outputs, which might require external modules for certain applications.
| Series | EASY-E4 |
|---|---|
| Model Part Number | 197211 EASY-E4-UC-12RC1 |
| Brand | Eaton |
The relay outputs can switch a maximum current of 8A.
This particular model does not have specific SIL or Performance Level certifications according to IEC 61508 or EN ISO 13849-1, so it may not be suitable for safety-critical applications without additional safety components.
Programming can be done using the integrated display and buttons for basic logic, or more advanced programming can be achieved using the Eaton EASY-SOFT software on a PC connected via Ethernet.
It features 8 digital inputs, of which 4 can be configured to function as analog inputs.
No, the EASY-E4-UC-12RC1 model does not have analog outputs. It is equipped with 4 digital relay outputs.
The degree of protection is IP20, which means it is protected against solid objects larger than 12.5mm but not against water.
Yes, the EASY-E4 series is designed to be expandable, allowing you to add more I/O modules to meet changing project requirements.
Verify the power supply voltage is within the specified range (12/24 V DC or 24 V AC) and check all power connections for security.
Check wiring to the input terminals. Ensure the input signal voltage is correct for the configured input type (digital or analog) and that the input is not overloaded.
Confirm the output relay is rated for the load being controlled and that the control logic within the program is correctly set to activate the output. Check wiring to the load.
Ensure the Ethernet cable is properly connected. Verify the IP address settings on the module and the network are correct and that no network conflicts exist.
Check the power supply. If power is present and the display is still blank, the unit may require service.
Setup:
Compatibility:
Care: