Setup, Compatibility & Care
- Preparation: Ensure the heating system is cold and turned off.
- Dosage: Add 1 liter of EVERBUILD P11 to the system for every 100 liters of water capacity.
- Application: Pour the product into the system, typically through the filling loop or a radiator.
- Circulation: Run the heating system for at least one hour to allow the cleaner to circulate.
- Flushing: Drain the system and flush with clean water until the water runs clear.
- Refilling: Refill the system and add a suitable inhibitor.
Compatibility: This product is compatible with plastic tanks, micro bore systems, and all metals (including aluminium) used in central heating systems. However, it's suitable only for fully indirect systems. It is not suitable for use in PRIMATIC single feed cylinders.
Care: Always follow the manufacturer's instructions. Wear appropriate protective clothing, gloves, and eye protection. Dispose of the product responsibly, according to local regulations.